Cornelius 175 8 Valve Beverage Dispenser User Manual


 
4
620917901OPR
B. Sanitize syrup lines, B-I-B Systems
a. Remove all the quick disconnects from all the B-I-B containers.
b. Fill a suitable pail or bucket with soap solution.
c. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water.
d. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
e. Rinse the B-I-B disconnects in the sanitizing solution.
f. Sanitizing fittings must be attached to each B-I-B disconnect. If these fittings are not available, the
fittings from empty B-I-B bags can be cut from the bags and used. These fittings open the discon-
nect so the sanitizing solution can be drawn through the disconnect.
g. Place all the B-I-B disconnects into the pail of sanitizing solution. Operate all the valves until the
sanitizing solution is flowing from the valve. Allow sanitizer to remain in lines for fifteen
(15) minutes.
h. Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution. Rinse
with clean water and reassemble the nozzle and syrup diffuser to the valve.
i. Remove the sanitizing fittings from the B-I-B disconnects and connect the disconnects to the ap-
propriate B-I-B container. Operate the valves until all sanitizer has been flushed from the system
and syrup is flowing freely.
C. Sanitize Flavor syrup lines, BIB System
a. Remove all the quick disconnects from all the BIB containers.
b. Fill a suitable pail or bucket with soap solution.
c. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water.
d. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution.
e. a. Rinse the BIB disconnects in the sanitizing solution.
f. b. Sanitizing fittings must be attached to each BIB disconnect. If these fittings are not avail-
able, the fittings from the empty BIB bags can be cut from the bags and used. These fittings
open the disconnect so the sanitizing solution can be drawn through the disconnect.
g. c. Place all the BIB disconnects into the pail of sanitizing solution. Purge all the flavor valves
until the sanitizing solution is flowing from inner nozzle. This can easily be accomplished by hold-
ing down each keypad button for at least 15 seconds. After 15 seconds the valve will go into
purge mode and continuously dispense for the next 60 seconds. Allow sanitizer to remain in lines
for at least thirty (30) minutes.
h. Remove nozzle cover (outer nozzle) from flavor module housing. Clean in a soap solution and
rinse with clean water.
i. Remove the sanitizing fittings from the BIB disconnects and connect the disconnects to the ap-
propriate BIB container. Operate the flavor valves until all sanitizer has been flushed from the
system and flavor syrup is flowing freely.