Cornelius QUANTUM SERIES Beverage Dispenser User Manual


 
Quantum Series Installation and Service Manual
720901120 - 14 -
No concentrate dis-
pensed, water only
Dispense tube not fully
engaged into recepta-
cle on concentrate
pouch
Refer to Concentrate Loading sec-
tion of this manual
Dispense tube discon-
nected from mixing
chamber
Refer to Concentrate Loading sec-
tion of this manual
Slide block on pump in
open position
Close and lock the slide block.
Refer to Concentrate Loading
section of this manual
Switch on pump platform in
FLUSH position
Move switch to RUN position
Concentrate too cold, not
properly thawed
Concentrate should be 34
o
F -40
o
F
(1.1
o
C –4.5
o
C) prior to loading
Defective pump motor Replace pump motor
Excessive remnant left
in empty concen-
trate pouch
Concentrate pouch improp-
erly thawed
Concentrate should be 34
o
F -40
o
F
(1.1
o
C –4.5
o
C) prior to loading
Concentrate pouch and/or
dispense tube improp-
erly installed
Refer to Concentrate Loading sec-
tion of this manual
Concentrate refill light
comes on prema-
turely
Concentrate pouch improp-
erly thawed
Concentrate should be 34
o
F -40
o
F
(1.1
o
C –4.5
o
C) prior to load-
ing.
Concentrate pouch and/or
dispense tube improp-
erly installed
Refer to concentrate loading sec-
tion of this manual
Loose wiring Check wiring connections between
the pump motor and the VRB
board
Bad VRB board Replace VRB board
Bad pump motor Replace pump motor
Concentrate refill light
does not come on at
all
Pump improperly locked or
pump is open
Close and lock Pump
Run/flush switch is in the
FLUSH position
Move switch to the RUN position