Cornelius QUANTUM SERIES Beverage Dispenser User Manual


 
Quantum Series Installation and Service Manual
720901120 - 18 -
Sold Out light illumi-
nates when concen-
trate no longer
passes through the
pump.(con’t)
Improper loading proce-
dures will usually result
in low brix conditions
and thus erratic sold out
indications.
Check that the pouch of juice is
properly loaded in the pouch
holder. Tube fitting should be
located at the bottom of the
pouch holder and the tube
should be approximately cen-
tered in the bottom portion of
the opening of the holder.
Check that the tube is correctly
loaded in the pump and the
pump is fully locked (top and
bottom slide pins should be
fully engaged into the pump
body).
Tube has been stretched
through pump when it
was loaded. Pouch may
not be seated correctly.
Adjust pouch. If pouch is loaded
correctly there should be ample
tube to reach the mixing cham-
bers without stretching the
tube.
Check that the rollers on the
pump are spinning
freely with no tube in
place.
If the rollers are sticky or locked up
see the platform removal and
cleaning procedure.
Sold Out light fails to
reset itself after door
is opened and
closed (Sold Out
light stays illumi-
nated)
Check the operation of the
reset switch located at
the bottom left hand
side of the door.
Adjust Switch.