Cornelius ED-250 BCP Beverage Dispenser User Manual


 
12
620916501INS
Trouble RemedyProbable Cause
NO ICE DISPENSED FROM
ICE PORTION CONTROLLER
ICE PORTION CONTROLLER
(CONTINUED)
D. Insufficient or no CO
2
supply
to dispenser.
D. Restore CO
2
supply to dispenser.
E. Ice chute cover not properly
Installed.
E. Make sure that cover is “snapped”
into place.
F. Defective ice chute interlock
switch.
F. Replace interlock switch.
G. Defective interlock relay. G. Replace relay.
H. Defective 24V transformer. H. Replace transformer.
I. Defective portion controller.
J. Defective ice gate cylinder.
K. Defective ice gate solenoid
valve.
L. Agitation relay wiring incorrect.
M. Defective agitation relay.
N. Defective agitator motor or
start capacitor or start relay.
I. Replace controller.
J. Replace cylinder.
K. Replace solenoid valve.
L. Red wire should be connected to
“+” terminal (no. 3) of relay coil.
M. Replace relay.
N. Replace defective component.
NO ICE DISPENSED FROM
MANUAL ICE DISPENSE
PUSHBUTTON SWITCH
A. Manual/Auto toggle switch in
“Auto” position.
B. Insufficient or no CO
2
supply to
dispenser.
A. Move toggle switch to “Manual”
position.
B. Restore CO
2
supply to dispenser.
C. Defective 24V transformer.
D. Defective manual override
solenoid valve.
E. Defective manual ice dispense
pushbutton switch.
C. Replace transformer.
D. Replace valve.
E. Replace switch.
F. Defective agitator motor or
start capacitor or start relay.
G. Defective ice gate cylinder.
F. Replace defective component.
G. Replace cylinder
ICE DISPENSING DURING
AUTOMATIC AGITATION
A. Manual/Auto toggle switch in
“manual” position.
A. Move toggle switch to “auto”
position.
B. Defective ice gate cylinder.
C. Defective ice gate solenoid
valve.
D. Defective portion controller.
B. Replace cylinder.
C. Replace valve.
D. Replace controller.