Cornelius Non-Carbonated Post-Mix Beverage Dispenser Beverage Dispenser User Manual


 
Non-Carbonated Impulse Installation & Operations Manual
© 2003, IMI Cornelius Inc. - 5 - Publication Number: 859000159INS
Adjusting Flow Rates
Flow rates of the water and concentrate are adjusted based on the desired ratio. For example: if the
desired ratio is 5:1, then the flow rate of the water is 5 times that of the concentrate.
If the desired finished drink flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./sec.
and the concentrate flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con-
centrate flow rate.)
Flow Rates oz./sec. Based on 5:1 Ratio
Finished Drink oz./sec. Water oz./sec.
Concentrate oz./
sec.
1.5 1.25 .25
2.0 1.67 .33
2.5 2.08 .42
3.0 2.5 .50
3.5 2.92 .58
4.0 3.33 .67
4.5 3.75 .75