Cornelius R-134A Refrigerator User Manual


 
312021002
20
Trouble RemedyProbable Cause
WATER PUMP CAPACITY
TOO LOW.(CONTD)
C. Water filter clogged. C. Replace water filter cartridge as
instructed.
D. Inoperative water pump. D. Call Service Person
TROUBLESHOOTING REFRIGERATION SYSTEM
Trouble Probable Cause Remedy
COMPRESSOR DOES NOT
OPERATE.
A. Ice bank sufficient. A. Refrigeration not called for
B. Electrical power to cooling unit
turned off.
B. Turn on electrical power to
Cooling Unit.
C. No cooling unit power source.
Blown fuse or tripped circuit
breaker.
C. Replace fuse or reset circuit
breaker.
D. Inoperative compressor. D. Call Service Person.
COMPRESSOR OPERATES
CONTINUOUSLY BUT DOES
NOT FORM SUFFICIENT ICE
BANK.
A. Cooling capacity is exceeded
by overdrawing.
A. Reduce amount of drinks drawn
per given time.
B. Cooling unit located in
excessively hot area or air
circulation through condenser
coil is restricted
B. Relocate unit or check and if
necessary, clean condenser coil
as instructed.