MAINTENANCE
Regular maintenance and cleaning will ensure good performance and reliability, while
extending the working life of the hood. Special attention should be paid to the grease
filters and to the charcoal filters when the hood is used in the recirculation mode.
Metal grease filters
Cleaning
The metal grease filter should be cleaned
every two months with normal usage and can
be cleaned in a dishwasher or by hand using
a mild detergent or liquid soap.
Replacement
Remove the filters one at a time, pushing the
handle towards the rear of the hood (fig. 8).
When replacing, ensure that the handle faces
outwards.
ATTENTION - THERE COULD BE A
POSSIBLE FIRE HAZARD IF THE FILTERS
ARE NOT REPLACED ACCORDING TO
THESE INSTRUCTIONS.
Charcoal filters
Functioning
In the recycling mode the charcoal filters
absorb smells and odours. This hood is
designed to be fitted with two charcoal filters
on both sides of the fan unit (fig. 9). The
charcoal filter cannot be washed and should
be replaced at least every 4 months or more
frequently if the hood is used consistently.
Replacement
To remove the charcoal filters place on hand
on one filter at a time and turn it toward the
front part.
The charcoal filter can now be removed.
Always ensure to replace both filters at the
same time.
ATTENTION - THERE COULD BE A
POSSIBLE FIRE HAZARD IF THE FILTERS
ARE NOT REPLACED ACCORDING TO
THESE INSTRUCTIONS.