Ducting or Recirculation fitting
Ducting fitting
The cooker hood can be ducted to the outside using
either rigid or flexible fire retardant ducting of 120 or
150 mm. The choice is left to the installer. When 120
mm ducting is to be used it will be necessary to install
the reduction flange item
A on the air outlet fig. 4.
The installer should provide suitable ducting and sealing
material for the installation.
The cooker hood can also be ducted to the outside
through one of the rectangular openings located in either
side of the lower section of the chimney stack. In this
case the deflector (item D) should be fitted into the
spigot (item R) to close the aperture which is not used
(fig. 5).
If the hood is provided with the charcoal filters fitted,
the filters should be removed (see paragraph
Maintenance).
Recirculation fitting
The filtered air is returned to the room through the two
side grilles on U-shaped lower section
I, which are either
formed in the metal itself (fig. 6).
Fit the recirculation spigot item R into the round outlet
on top of the canopy while pressing down on the spigot
until it snaps into position.
Install the charcoal filters inside the canopy as instructed
in paragraph Maintenance).