8
Burner and nozzle characteristics
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95
Triple Crown
(TC)
130 3.25 1.5 63 91 236 232 133 309
Oven - 3.02 1.0 49 85 219 216 132 288
Grill - 2.50 - - 80 182 179 122 227
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
TC
A
S
R
K 642 G/G K 647 GS/G
K 642 GS/G K 647R G/G
K 642R GS/G
K 643 G/G
K 6432 G/G
K 645 G/G
K 645R G/G