4
Electrical Connection
Your appliance is now supplied with a 13 amp fused plug
that can be plugged into a 13 amp socket for immediate
use. Before using the appliance please read the
instructions below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA approved
fuse to BS 1362 should always be used, and the fuse
cover re-fitted. If the fuse cover is lost, the plug must not
be used until a replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of the correct
colour as indicated by the coloured marking or the colour
that is embossed in words on the base of the plug.
Replacements can be obtained directly from your nearest
Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug and
you should wish to remove it to add a cable extension or
to re-route the mains cable through partitions, units etc.,
please ensure that either:
- the plug is replaced by a fused 13 amp re-wireable
plug bearing the BSI mark of approval
or:
- the mains cable is wired directly into a 13 amp cable
outlet, controlled by a switch, (in compliance with BS
5733) which is accessible without moving the
appliance.
Please note: for appliances with a rating greater than 13
amp (eg: electric hob, double ovens and freestanding
electric cookers etc.) the mains cable must be wired into
a cooker output point with a rating of 45 amp. In this case
the cable is not supplied.
Disposing of the plug:
Ensure that before disposing of the plug itself, you make
the pins unusable so that it cannot be accidentally inserted
into a socket.
Instructions for connecting cable to an alternative plug:
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect Green & Yellow wire to terminal marked "E" or
or coloured Green or Green & Yellow.
Connect Brown wire to terminal marked "L" or coloured
Red.
Connect Blue wire to terminal marked "N" or coloured
Black.
If a 13 amp plug (BS 1363) is used it must be fitted with a
13 amp fuse. A 15 amp plug must be protected by a 15
amp fuse, either in the plug or adaptor or at the distribution
board.
If you are in any doubt about the electrical supply to your
machine, consult a qualified electrician before use.
How to connect an alternative plug:
The wires in this mains lead are coloured in accordance
with the following code:
GREEN &
YELLOW
BROWN
BLUE
13 amp fuse
CROSS-BAR
CORD GRIP
BLUE "NEUTRAL" ("N")
BROWN "LIVE" ("L")
GREEN AND YELLOW "EARTH" ("E")
Disposing of the appliance:
When disposing of the appliance please remove the plug
by cutting the mains cable as close as possible to the
plug body and dispose of it as described above.
Adaptation to the different types of gas
The cooker is supplied adjusted for natural gas
(methane).
To adapt the cooker to a type of gas which is different
from the one it was designed for the following operations
must be carried out:
Important: disconnect the cooker from the electricity.
1) Replacement of nozzles and regulating air.
a) Upper burners
• Remove grids, flame separator plates and burners from
the hob.
• Loosen screws “A” (see Fig. C) remove bushes from
work top and lift the latter up.
• Loosen screws “B” and lift the pipe “C” (Fig. D).
• Unscrew the nozzles and replace them (see Fig. D)
with those suitable for the new gas as supplied with
the cooker in accordance with table 2.
• To regulate the amount of air to the burner, adjust hose
“C” according to the values indicated in table 1, “Air
Regulation for Burners”. Once the adjustment is made,
fix hose “C” with the screw “B” (Fig. D).
A
B
C
B
A