Indesit PZ 640T GH NG Cooktop User Manual


 
6
Service Details
Post installation checks
Leak Check
Ensure all gas control knobs are in the Off position.
Ensure the gas supply is switched on.
Spray a solution of soapy water onto all gas joints as well
as the full length of any exible hoses.
UNDER NO CIRCUMSTANCES USE A NAKED FLAME
IN CHECKING FOR LEAKS.
If bubbles appear anywhere, turn the gas supply off, check
all connections and retest. If satisfactory operation cannot be
achieved, contact place of purchase or their appointed agent
for service.
Flame check
Turn each burner on, and ensure that the ame is blue with
minimal yellow tipping. If there is signi cant yellow tipping,
ame lift off or excessive noise, check pressure and adjust at
the regulator if necessary.
If satisfactory operation cannot be achieved, contact place of
purchase or their appointed agent for service.
Igniter operation
Check that the igniter for each burner successfully ignites the
gas.
If an igniter fails to work, rst remove the plug from the
electrical power outlet, and then check that all the electrical
connections are in place.
If satisfactory operation cannot be achieved, contact place of
purchase or their appointed agent for service.
Low ame setting
Check the low ame setting for each hob burner to ensure
that the minimum ame will not be extinguished by air
draughts.
Light the burner.
Turn the control until it engages in the minimum position.
Ensure the ame is stable and will not be extinguished by
air draughts.
To adjust the minimum ame:
Follow the procedure described in the gas conversion in-
struction.
Electrical equipment and components
To check or replace the ignition module
Electrical components are located below the hob surface. To
access the components:
IMPORTANT: First ensure that gas and electrical power
are disconnected before performing any service to this
appliance.
Remove the control knobs, trivets, burner caps and burner
head assembly.
Invert the cooktop and remove the two screws on the base
near the gas manifold.
Lift the base upwards. Take care to ensure that no dam-
age occurs to the spark ignition leads or the igniter com-
ponents.
The electronic ignition module is now easily accessible for
service or replacement.
Assembly is a reversal of the above procedure.
To check or replace the gas controls and gas manifold
Gas components are located below the hob surface.
Access the components underneath the surface of the hob
as described in the previous section.
Disconnect all ancillary gas piping, wiring and any screws,
as appropriate.
The gas manifold may then be extracted.
Replacement is a reversal of the above procedure.
ALWAYS PERFORM A LEAK CHECK AFTER PERFORM-
ING ANY SERVICE. Correct procedure is at the top of
this page.
Adjust turn down setting
Put the tap to the low ame position;
Remove the tap knob and turn the adjusting screw, situ-
ated inside the tap stem ( g.11), using a screwdriver
(loosening the screw increases the height of the ame,
tightening decreases it). note: the adjusting screw must be
fully screwed down for liquid gas.
Having obtained the low ame setting required and with
the burner lit, abruptly change the position of the knob
several times from minimum to maximum and vice versa
and check that the ame does not go out.
DO NOT MODIFY THIS APPLIANCE IN ANY WAY.