Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or
burns. Use care when operating this appliance.
Property Damage: Join remaining tube
to cold water supply only.
Property Damage: Join remaining tube
to cold water supply only.
B
Turn on the cold water supply.
Depress
the dispenser’s HOT handle
and hold it until water flows from
the spout (approximately 1 to 2 minutes).
Run the water for at least 2 minutes to
flush lines (both the hot and cold handles
independently if applicable).
A
A
6
Check all connections to ensure they are
tight
and that there are no leaks.
Plug in instant hot water tank.
Water will be cold at first.
Allow 12-15 minutes for water to reach
target temperature.
Gurgling or hissing is normal during the
initial heating cycle.
5
Install a T-fitting (not included) onto the
cold water supply line.
Install dedicated water control valve with
3/8" compression fitting.
At the end of the white 3/8" tube from the
quick-connector, slide the supplied brass
nut and ferrule over the tube and then push
in the brass tube insert.
Insert the white 3/8" tube into the 3/8"
compression fitting and tighten.
HC-View/HC-Wave/HC3
Install a T-fitting (not included) onto the
cold water supply line.
Install dedicated water control valve with
1/4" compression fitting (not included).
At the end of the copper 1/4" tube,
slide the brass nut and ferrule provided
with the control valve over the tube.
Insert the copper tube into the 1/4"
compression fitting and tighten.
H-View/H-Wave/GN3/H990/H770
A
Property Damage: A standard grounded outlet within
30" of the dispenser is required under the sink. Do
not use an extension cord set with the dispenser.
Brass Nut
Plastic
tube
Ferrule
Brass Inser
tube
Copper
Brass Nut
Ferrule
FINAL WATER CONNECTION
FILL TANK & THEN CONNECT POWER