Jackson 200S Dishwasher User Manual


 
20
200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)
19. Using the small flathead screwdriver, lift out the screen
retainer. Verify that the holes in it are free of clogs and debris.
20. Again using the small flathead screwdriver, carefully
remove the mesh screen from inside the valve body. The
screen should be taken and rinsed out to remove any debris
fouling it.
21. With the mesh screen removed, look down into the valve
and verify it is not clogged. Remove any foreign objects from
the valve body that would obstruct flow.
22. Reassemble the valve, reversing the steps needed to take
it apart. Replace defective replacement parts with new parts
from ordered kits. Ensure that components are sufficiently
tightened to prevent leakage.
AFTER MAINTENANCE ACTIONS
Reconnect the incoming water (if disconnected) and
turn on. Then restore power to the unit. Run the unit for at
least 10 minutes to ensure there are no leaks. If any problems
arise please contact your Jackson representative.
SPECIAL PARTS
Solenoid Valve Plunger Kit
Includes plunger and spring
Part number 06410-003-07-40
Solenoid Valve Diaphragm Kit
Includes diaphragm and o-ring
Part number 06401-003-07-42 (3/4” NPT)
Solenoid Valve 24 Volt Coil and Housing
Part number 04810-100-06-18
Complete Solenoid Valve
Part number 04810-100-01-40 (3/4”, 24 Volt)
SECTION 5: SERVICE PROCEDURES
RINSE SOLENOID VALVE REPAIR PARTS KIT (CONTINUED)
Removing the screen retainer
Removing the mesh strainer screen
View inside the solenoid valve body