Jackson DELTA 5 D Dishwasher User Manual


 
Delta 5 Installation & Operation Manual 7610-003-37-08
Issued: 05-25-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
SPECIFICATIONS OF THE DELTA 5
2
OPERATING CAPACITY ( NSF RATED):
RACKS PER HOUR 29
DISHES PER HOUR 725
GLASSES PER HOUR 725
OPERATING CYCLES (SECONDS):
NORMAL
CYCLE:
WASH TIME 45
RINSE TIME 25
TOTAL CYCLE TIME 90
WASH TANK CAPACITY (GALLONS): 1.2
WASH PUMP CAPACITY (GPM): 61
OPERATING TEMPERATURES:
WASH (MINIMUM) (48.9°C) 120°F
WASH (RECOMMENDED) (60.0°C) 140°F
RINSE (MINIMUM) (48.9°C) 120°F
RINSE (RECOMMENDED) (60.0°C) 140°F
WATER REQUIREMENTS:
WATER LINE SIZE NPT 1/2”
DRAIN LINE SIZE NPT 2”
FLOW PRESSURE 20 ±5 PSI
MINIMUM CHLORINE REQUIRED (PPM): 50
ELECTRICAL REQUIREMENTS:
WASH PUMP MOTOR HP 3/4
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ RATINGS AMPS CIRCUIT
115 1 60 2KW@110V *16 A 20 AMP
* This dishmachine is designed so that the wash motor is never
running when the wash heater is on. Service load is based upon
the higher of the two amperages.
NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip
circuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is
displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets
all applicable national and local codes. These numbers are
provided in this manual simply for reference and may change
without notice at any given time.
FRAME DIMENSIONS:
WIDTH (622.3mm) 24 1/2”
DEPTH (641.35mm) 25 1/4”
DEPTH, WITH FRONT DOOR OPEN (933.45mm) 36 3/4”
HEIGHT (990.6mm) 39”
MAXIMUM WASH
CHAMBER CLEARANCE (292.1mm) 11 1/2”
FRAME DIMENSION (DOUBLE DOOR):
WIDTH (622.3MM) 24 1/2”
DEPTH (714.375MM) 28 1/8”
DEPTH, WITH DOOR OPEN (1311.275MM) 51 5/8”
HEIGHT (990.6MM) 39”
CHAMBER CLEARANCE (292.1MM) 11 1/2”
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.