Jackson JP-24F Dishwasher User Manual


 
JP-24 Technical Manual 7610-002-49-79 Rev. D
Issued: 03-06-2006 Revised: N/A
SECTION 6: PARTS SECTION
CYCLE COUNTER RETROFIT KIT
50
Instructions for Adding Cycle Counter to JP
-
24 Undercounter Dish Machi
ne
1. Locate the template on the front of the plastic control panel in the approximate location as
shown in the diagram below.
2. Use a 3/32” diameter drill bit to drill the four mounting holes through the plastic control
panel.
3. Mount the template to the front of the control panel using the screws and locknuts provided.
4. Using the template as a guide, cut the 1-3/8” x 1-
1/8” cutout (the inside of the template) from
the plastic control panel. Use a Dremel tool (or similar) or drill multiple holes along the edge
of the template in order to cut away the cutout.
5. Remove the template from the control panel.
6. Assemble the counter (with mounting plate) to the control panel using the four screws and
locknuts provided.
7. One lead wire from the counter is connected together with the blue wires from the fill
solenoid valve and the rinse/fill light (using the existing wire nut that connects these two
wires together).
8. The other lead wire from the counter is connected together with the red wires from the fill
solenoid valve and the rinse/fill light (using the existing wire nut that connects these two
wires together).
9. The counter should increment each time the fill solenoid valve is turned on.
Template, Cycle Counter Mount
05700-002-94-37
Cycle Counter Mount
05700-002-94-36
To order the complete Cycle Counter Retrofit Kit with hardware,
use part number 06401-002-95-14.
Instruction Sheet
05700-002-95-15
Cycle Counter, 240V
05990-111-47-42