Jackson JPX-300H Dishwasher User Manual


 
JPX-300 Installation/Operation Manual 7610-002-71-26 Rev. J
Issued: 03-09-2006 Revised: 03-06-2007
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
11
To access the programming mode, the machine must be ON, and idle (between cycles).
On the timer board, press and hold both the MOVE and ENTER buttons on the timer board simultaneously for two seconds.
The PROGRAM (PGM) light and light A will illumniate.
Note: Once in the programming mode, the MOVE button is used to scroll between the programming categories and the ENTER
button is used to select the category.
Press the MOVE button to move the solid light to the desired location of FILL, RINSE AID, DETERGENT or SANITIZER. Please
note that options A, B, C, and D are not adjustable outputs.
Press the ENTER button for the chosen category. Now, the (PGM) light will illuminate along with lights corresponding to the
time values forthe chosen category. The ACCEPT light will blink.
The PROGRAM light will illuminate.
To change the value of a parameter, use the MOVE button to illuminate the light next to the time option (time is in seconds). In
the time categories, each second in use will light up. To deselect the option, press ENTER and the light will go off, press ENTER
again and it will illuminate. Once you have set your time category, press the MOVE button until the ACCEPT light illuminates
and press ENTER. This will save the changed parameters.
Once you press the ENTER button when the ACCEPT light is blinking you will exit the programming mode. To change any other
values, you will have to return to the programming mode. To revert back to a previous setting, you must return to that option
and change the parameter back to the previous setting.
Once in the programming mode, if there have been no keypad inputs for approximately 2 minutes, the system will automati-
cally exit out of the programming mode. Any changes to parameters will be saved when the programming mode is automati-
cally exited.
The wash and drain settings are not adjustable.
All time adjustments are in seconds. Refer to the chart below for the adjustable outputs.
PROGRAMMING INSTRUCTIONS FOR CHEMICAL FEEDER PUMPS (FOR INSTALLATION TECHNICIAN ONLY)
Time in seconds.
Timer Programming Board
JPX-300H JPX-300L
Not adjustable Rinse Aid
Rinse Fill
Detergent Sanitizer
Rinse Aid Detergent