SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
8
VISUAL INSPECTION: Before installing the unit, check the container and machine for damage. A damaged container is an indi-
cator that there may be some damage to the machine. If there is damage to both the container and machine, do not throw away
the container. The dishmachine has been inspected and packed at the factory and is expected to arrive to you in new, undam-
aged condition. However, rough handling by carriers or others may result in there being damage to the unit while in transit. If
such a situation occurs, do not return the unit to Jackson; instead, contact the carrier and ask them to send a representative to
the site to inspect the damage to the unit and to complete an inspection report. You must contact the carrier within 48 hours of
receiving the machine. Also, contact the dealer through which you purchased the unit.
UNPACKING THE DISHMACHINE: Once the machine has been removed from the container, ensure that there are no miss-
ing parts from the machine. This may not be obvious at first. If it is discovered that an item is missing, contact Jackson imme-
diately to have the missing item shipped to you.
LEVEL THE DISHMACHINE: The dishmachine is designed to operate while being level. This is important to prevent any dam-
age to the machine during operation and to ensure the best results when washing ware. The unit comes with adjustable bullet
feet, which can be turned using a pair of channel locks or by hand if the unit can be raised safely. Ensure that the unit is level
from side to side and from front to back before making any connections.
PLUMBING THE DISHMACHINE: All plumbing connections must comply with all applicable local, state, and national plumb-
ing codes. The plumber is responsible for ensuring that the incoming water line is thoroughly flushed prior to connecting it to
any component of the dishmachine. It is necessary to remove all foreign debris from the water line that may potentially get
trapped in the valves or cause an obstruction. Any valves that are fouled as a result of foreign matter left in the water line, and
any expenses resulting from this fouling, are not the responsibility of the manufacturer.
CONNECTING THE DRAIN LINE: The drain for the Tempstar models covered in this manual are gravity discharge drains. All
piping from the 1-1/2” FNPT connection on the wash tank must be pitched (1/4” per foot) to the floor or sink drain. All piping
from the machine to the drain must be a minimum 1-1/2” NPT and shall not be reduced. There must also be an air gap between
the machine drain line and the floor sink or drain. If a grease trap is required by code, it should have a flow capacity of 5 gal-
lons per minute.
NOTE: This equipment is not recommend for use with deionized water or other aggressive fluids. Use of deion-
ized water or other aggressive fluids will result in corrosion and failure of materials and components. Use of
deionized water or other aggressive fluids will void the manufacturer's warranty.
WATER SUPPLY CONNECTION: Ensure that you have read the section entitled “PLUMBING THE DISHMACHINE” above
before proceeding. Install the water supply line (1/2” pipe size minimum) to the dishmachine line strainer using copper pipe. It
is recommended that a water shut-off valve be installed in the water line between the main supply and the machine to allow
access for service. The water supply line is to be capable of 25 PSI “flow” pressure at the recommended temperature indicat-
ed on the data plate. For the Tempstar GPX, the line should also have the capacity to supply 52.2 GPH @ 25 PSI “flow” pres-
sure.
For the Tempstar HH GPX, the line should also have the capacity to supply 72 GPH @ 25 PSI “flow” pressure.
In areas where the water pressure fluctuates or is greater than the recommended pressure, it is suggested that a water pres-
sure regulator be installed. The Tempstar models covered in this manual come with water pressure regulators as standard
equipment. Please notify Jackson immediately if this component is not present on your machine.
Do not confuse static pressure with flow pressure. Static pressure is the line pressure in a “no flow” condition (all valves and
services are closed). Flow pressure is the pressure in the fill line when the fill valve is opened during the cycle.
It is also recommended that a shock absorber (not supplied with the Tempstar models) be installed in the incoming water line.
This prevents line hammer (hydraulic shock), induced by the solenoid valve as it operates, from causing damage to the equip-
ment.
WATER CONNECTION TO THE GAS BOOSTER HEATER: Refer to page entitled “GAS BOOSTER HEATER CONNEC-
TIONS”.