Ducting Information
(Model CVE407 only)
Jenn-Air's ventilationsystem isdesignedto capture bothcookingfumes andsmoke from
any place on the cooktop surface. If the system does not, these are some ducting
installation situations to check:
• 6" diameter round or 3 1/4"x 10" rectangular ducting should be used. Note: 5"
diameter round ducting may be used for venting straight out the back of the
cooktop and directly through the wall for 10'or less.
• No morethan three 90°elbows should be used. Distancebetween elbows should
be at least 18".
• Recommended Jenn-Air wall cap should be used. Make sure damper moves
freely when ventilation system is operating.
• There should be a minimum clearance of 6"for cooktop installed neara side wall.
If there is not an obvious improper installation, there may be a concealed problem such
as a pinched joint, obstruction in the pipe, etc. Installation is the responsibility of the
installerandquestions shouldbeaddressedfirst bythe installer. The installershouldvery
carefully check the ducting installation instructions.