Jenn-Air CVE1400 Cooktop User Manual


 
Cooktop cartridges can be installed in most cooktops.
conventional coil, halogen, radiant, or solid element.
Cartridge options include
[ To Install Cartridges ]
1. If the grill grates, element, and/or grill-rocks are in place, remove before installing
a cooktop cartridge. Clean basin pan of any grease accumulation. (See page 16
for cleaning recommendations.)
2. To install any of the optional cooktop cartridges, be sure controls are OFF. Position
the cartridge terminal plug towards the terminal receptacle.
3. Slide the cartridge towards the receptacle until the cartridge terminal plug is
completely engaged.
4. Lower the opposite end of the cartridge into the cooktop until it is flush with the
surface. Your cooktop is now ready to use.
iTo Remove Cartridges i
1. Controls must be OFF and the cartridge should be cool.
2. Lift up on the "tab" located on the cartridge until top of cartridge clears the opening
of the cooktop by about 2 inches. Lifting the cartridge too high while still engaged
in the receptacle could damage the terminal plug.
3. To disengage terminal, hold cartridge by the sides and slide away from the terminal
receptacle. Lift out when fully unplugged.
4. A storage tray, Model A350 is available and can be used for storing a cartridge.
5. Do not stack cartridges where they may fall or be damaged. Never store other
materials on top of a glass-ceramic cartridges since this could damage or mar the
surface.
Note: Remember to replace the air grille before using the ventilation system.
[,,,,,,,HomeCanning i
For best results, canning should be done on the conventional coil cartridge/cooktop.
Canning element accessory, Model A145A, makes it possible to use large oversized
canners with the conventional coil cartridge/cooktop.
For additiona/ information, refer to use and care manua/ packaged with your cartridge.
7