Jenn-Air JMW9530 Oven User Manual


 
FAULT
PROBLEM COMPONENTS TO CHECK
CODES
Power to element relay activated J1, J2 wire harnessconnection to control shorted. If
F1
during time of day display, checks ok, change control.
F2 Over temperature sensed Ohm TEST SENSOR. If checks ok, change control.
F3 Open sensor. Ohm sensor.
F4 Shorted sensor. Ohm sensor.
F5 Over temperature Ohm sensor. Check connection of sensor wire harness.
F7 Shorted key Stuck Function Key on control.
F9 Door Code Check LatchAssembly.
For Models:
W27100, W27200, W30100, WW27210, WM27260 (Oven Sensor Chart: Please refer to chart below)
MEAT PROBE:
TYPE:
CALIBRATION:
NTC thermistor
9938 ohms (150 F)
PROBE RESISTANCE VS TEMR TABLE
DEGREES F RESISTANCE
122 18963 ohms
150 9938
156.2 8846
165.2 7456
210.1 3886
OVEN SENSOR:
SENSOR TYPE:
CALIBRATION:
RTD 1000 ohm platinum
1654 ohms (350 F)
OVEN SENSOR RESISTANCE VS TEMR TABLE
DEGREES F RESISTANCE
100 1143 ohms
200 1350
300 1553
350 1654
400 1753
500 1949
600 2142
700 2331
800 2516
900 2697
1000 2874
For Models:
W27400, W30400, W30400RWW27430, WW27430RWW30430, WW30430RWM27460,
WM30460, JJW8527, JJW85300 JJW86270 JJW8630, JJW9527, JJW9530, JJW9627, JJW9630,
JMW8527, JMW8530, JMW9527, JMW9530
16009721 COMPONENT DESCRIPTION 1-3
©1999 Maytag Appliances Sales Company