Jenn-Air W10253462A Cooktop User Manual


 
11
5. Mount blower motor to the floor with 4 - #8 x ¾" hex head
screws provided.
6. Go to the “Electrical Connection” section.
Floor Venting
1. Mark the floor at the center of the cabinet opening.
2. Position template on floor by matching the centerline of the
template to the centerline drawn on the floor and place
template 2¼" (5.7 cm) from the back wall.
3. Determine the correct position for the vent hole, depending
on obstructions (joists) in the floor.
The hole can be cut anywhere within the boundaries of either
hatched area.
Option 1: If using the back hatched area (bigger one), the
blower inlet must face the left side as shown on the template
Option 2: If using the front hatched area (smaller one), the
blower inlet must face the back.
NOTE: If the template is misplaced, the following
measurements can be used to determine the vent hole
location.
4. Draw and cut a 6¼" (15.8 cm) diameter hole (option 1 shown).
5. Position blower motor in cabinet opening and mount blower
motor to the floor.
Top View
Top View
Option 1 Option 2
A.Inlet from range
B.Exhaust outlet
A
A
B
B
Top View
A.9" (22.8 cm)
B.3
¹⁄₈
" (7.9 cm)
C.8
³⁄₈
" (21.3 cm)
D.6
³⁄₈
" (16.2 cm)
E.2¼" (5.7 cm)
F. 12½" (31.7 cm)
G.18¾" (47.6 cm)
H.1½" (3.8 cm)
I.3½" (8.9 cm)
A.Option 1
B.Option 2
Top View
Option 1 Option 2
A.Inlet from range
B.Exhaust outlet
A
B
C
D
E
F
G
H
I
A
B
A
A
B
B