Dimensions of recessDimensions of recess
Dimensions of recessDimensions of recess
Dimensions of recess
Height 580 mm
Width 560 mm
Depth 550 mm
Dimensions of the oDimensions of the o
Dimensions of the oDimensions of the o
Dimensions of the o
vv
vv
v
en caen ca
en caen ca
en ca
vityvity
vityvity
vity
Height 335 mm
Width 395 mm
Depth 400 mm
Oven capacity 53 litres
InstallationInstallation
InstallationInstallation
Installation
Heating elements ratingHeating elements rating
Heating elements ratingHeating elements rating
Heating elements rating
Conventional Oven (Top element+Bottom element) 1,800 W
Top element 800 W
Bottom element 1,000 W
Fan Oven 2,000 W
Inner Grill element 1,650 W
Full Grill element 2,450 W
Pizza Oven 2,000 W/1,000 W
Pyrolytic cleaning function 2,450 W
Thermal Grilling 1,675 W
Convection Fan 25 W
Oven Light 40 W
Cooling Fan 25 W
Total Rating 2,500 W
Supply voltage (50 Hz) 230 V
THIS OTHIS O
THIS OTHIS O
THIS O
VEN MUST BE EARVEN MUST BE EAR
VEN MUST BE EARVEN MUST BE EAR
VEN MUST BE EAR
THEDTHED
THEDTHED
THED
Electrical RequirementsElectrical Requirements
Electrical RequirementsElectrical Requirements
Electrical Requirements
Any permanent electrical installation must comply with the
latest I.E.E. Regulations and local Electricity Board regulations.
For your own safety this should be undertaken by a qualified
electrician, e.g. your local Electricity Board, or a contractor
who is on the roll of the National Inspection Council for
Electrical Installation Contracting (NICEIC).
Electrical ConnectionElectrical Connection
Electrical ConnectionElectrical Connection
Electrical Connection
The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
Before connecting to the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate on
the side of the oven door.
The oven has an easily accessible terminal block which is
marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
or E - Earth terminal
The cable used to connect the oven to the electrical supply
must comply to the specifications given below.
It is necessary that you install a double pole switch between
the oven and the electricity supply (mains), with a minimum
gap of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the current
rules.
The switch must not break the yellow andThe switch must not break the yellow and
The switch must not break the yellow andThe switch must not break the yellow and
The switch must not break the yellow and
green earth cable at any point.green earth cable at any point.
green earth cable at any point.green earth cable at any point.
green earth cable at any point.
It is necessary that the yellow/green earthIt is necessary that the yellow/green earth
It is necessary that the yellow/green earthIt is necessary that the yellow/green earth
It is necessary that the yellow/green earth
wire is about 2 cm longer than the live andwire is about 2 cm longer than the live and
wire is about 2 cm longer than the live andwire is about 2 cm longer than the live and
wire is about 2 cm longer than the live and
neutral ones.neutral ones.
neutral ones.neutral ones.
neutral ones.
ImportantImportant
ImportantImportant
Important
After installation and connecting, the cable must be placed
so that it cannot at any point reach a temperature of more
than 60°C above the ambient temperature.
Before the oven is connected, check that the main fuse and
the domestic installation can support the load; and that the
power supply is properly earthed.
The manufacturer disclaims any responsibility should these
safety measures not be carried out.
ConnectionConnection
ConnectionConnection
Connection
Min. sizeMin. size
Min. sizeMin. size
Min. size
Cable / flexCable / flex
Cable / flexCable / flex
Cable / flex
FuseFuse
FuseFuse
Fuse
viavia
viavia
via
Cable/flexCable/flex
Cable/flexCable/flex
Cable/flex
typetype
typetype
type
Cooker 2.5 mm
2
PVC/PVC 20 A
Control twin and
Circuit earth
For UK use onlyFor UK use only
For UK use onlyFor UK use only
For UK use only
FF
FF
F
or Euror Eur
or Euror Eur
or Eur
ope use onlope use onl
ope use onlope use onl
ope use onl
yy
yy
y
Min. size Cable/flexMin. size Cable/flex
Min. size Cable/flexMin. size Cable/flex
Min. size Cable/flex
Cable / flex typeCable / flex type
Cable / flex typeCable / flex type
Cable / flex type
FuseFuse
FuseFuse
Fuse
2.5 mm
2
H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
Electrical ConnectionElectrical Connection
Electrical ConnectionElectrical Connection
Electrical Connection