Keating Of Chicago 2000 Griddle User Manual


 
INTRODUCTION
Instructions in this manual should be read thoroughly
before attempting to operate this Miraclean® Griddle.
All installation and service on Keating equipment must
be performed by qualified, certified, licensed and/or
authorized installation or service personnel.
Service information for Keating equipment has been
prepared for use by qualified and/or authorized
personnel.
Keating equipment is made in the U.S.A. and has
American sizes of hardware. All metric conversions are
approximate.
INSTALLATION INSTRUCTIONS
Proper installation will assure top performance.
Alteration to your equipment will void the warranty.
Before uncrating, check equipment carefully for
damage.
IF EQUIPMENT ARRIVES
DAMAGED
Keating does not assume responsibility for loss or
damage incurred in transit.
IMPORTANT
This merchandise has been thoroughly inspected and
carefully packed before leaving our plant.
Responsibility for its safe delivery was assumed by the
carrier at the time of shipment. Claims for loss or
damage to the contents should, therefore, be made
upon the carrier, as follows:
CONCEALED LOSS OR DAMAGE
Concealed loss or damage means loss or damage
which does not become apparent until the
merchandise has been unpacked. The contents may
be damaged in transit due to rough handling even
though the carton may not show external damage.
When the damage is discovered upon unpacking,
make a written request for inspection by the carrier’s
agent within fifteen days of the delivery date. Then file
a claim with the carrier since such damage is the
carrier’s responsibility. By following these instructions
carefully, we guarantee our full support of your claims
to protect you against loss from concealed damage.
VISIBLE LOSS OR DAMAGE
Any external evidence of loss or damage must be
noted on the freight bill or express receipt, and signed
by the carrier’s agent. Failure to adequately describe
such external evidence of loss or damage may result in
the carrier refusing to honor a damage claim. The form
required to file such a claim will be supplied by the
carrier.
DO NOT RETURN DAMAGED MERCHANDISE
TO KEATING FILE YOUR CLAIM AS ABOVE.
FIRST STEPS
POSITIONING
Keep appliance area free and clear of any
combustibles. Position the Miraclean® Griddle 6
inches (152mm) from any combustible material. A
minimum of 24 inches (610mm) should be provided at
the front of the Miraclean® Griddle for servicing and
proper operation. Air for combustion enters the
Miraclean® Griddle from the bottom of the cabinet and
the bottom of the control panel.
DO NOT BLOCK BOTTOM OF MIRACLEAN
GRIDDLE CABINET. DO NOT OBSTRUCT FLUE.
Your Miraclean® Griddle is designed to be serviced
from the front with adequate clearance for air openings
into the combustion chamber servicing and operation.
MINIMUM CLEARANCE
Suitable for combustible floors.
VENTILATION
The Miraclean® Griddle must be installed in an area
providing adequate air supply and ventilation. Do not
obstruct the flow of combustion and ventilation air.
Proper ventilation is one of the important
considerations for efficient operation of the Miraclean®
Griddle. It should be installed so that the products of
combustion are removed efficiently without producing
drafts that will interfere with proper burner operation.
The area around the front and bottom of the
Miraclean® Griddle must be kept clear and
unobstructed. In the U.S.A. the ventilation systems
must conform to the ANSI/NFPA96 latest edition. “A
minimum of 18" (457mm) should be maintained
between the flue outlet and the lower edge of the
grease filters.” It is the responsibility of the owner and
the local installer to comply with national and local
codes.
NATIONAL CODE REQUIREMENT
The installation must conform with local codes, or in the
absence of local codes, with the National Fuel Gas
code, ANSI Z223.1 or the Natural gas Installation
Code, CAN/CGA-B49.1 or the Propane Installation
Code, CAN/CGA-B149.2. Keating equipment is
designed and manufactured to operate only on the type
of gas specified by the user and indicated on the serial
plate located on the front panel. The gas may be
natural, propane or manufactured. The type of gas
cannot be converted to another gas fuel by turning or
engaging a switch.
1
Clearances Combustible Noncombustible
Construction
Construction
Back 6" 0"
Right Side 6" 0"
Left Side 6" 0"