KitchenAid 3184330 Water Dispenser User Manual


 
Before you start...
Check location where hot water dispenser will be
installed. Proper installation is your responsibility.
Make sure you have everything necessary for
correct installation. It is the responsibility of the
installer to comply with installation specifications
provided and with state and local plumbing codes.
Faucet mounting: requires a 1 -l/l 6” to l-3/8”
diameter opening in sink or countertop for
mounting hot water dispenser faucet. Faucet can
be installed in place of sink sprayer. For other
installations, contact a qualified installer for best
procedure to drill a hole through your type of sink
or countertop. Thickness of sink or countertop hole
must not exceed 3/4”.
Dimensions shown must be used.
Proper cold water supply connection must be
available. (See “Water supply requirements,”
Panel B.)
Use saddle tapping valve supplied. Saddle
tapping valve is designed for use with 3/8” to l-
3/8” outer dimension (O.D.), soft copper tubing
(plain or chrome plated) or rigid metal pipe. Do Not
use the saddle valve with flexible ribbed tubing.
(See “Water supply requirements,” Panels B.)
Flexible ribbed tubing requires special connecting
hardware available from your local plumbing
supply.
Grounded electrical outlet is required.
(See
“Electrical requirements,” Panel B.) Outlet should
be located for easy connection to hot water
dispenser. The outlet should be within 30” of hot
water dispenser tank.
Panel A
.-
Electrical Shock Hazard
Special care must be taken when drilling
holes into walls or water pipes. Electrical
wires may be concealed behind the wall
covering or water may remain in pipes.
Failure to follow this instruction could result
in personal injury or death.
Personal Injury Hazard
Install faucet with lever to the side or behind
spout.
Failure to do so may result in hot water
scalding hand when operating lever.
Property/Product Damage
l Contact a qualified installer or licensed
plumber for the best procedure for cutting
a faucet opening in your type of sink or
countertop.
l Plumbing connections must comply with
all sanitary, safety and plumbing codes.
l Do Not store or operate hot water
dispenser below 32°F.
l Do Not use pipe sealing compounds. They
may get inside dispenser and cause an
unpleasant taste or smell.
l Dispenser must be filled with water and
thermostat turned to “OFF” position
before connecting to electrical power
supply-
Failure to follow these instructions may
result in water damage to property or
permanent product damage not covered by
the warranty.
Water connections use compression fittings which
do Not require sealing compounds to keep them
from leaking.
Important: Observe all governing codes and
ordinances.
NOTE:
This hot water dispenser is Not a water
purifier. Some installations may require a
filter (such as charcoal) for increased
satisfaction.
Top view
install faucet with lever to
the side or behind spout.
lever
spout
Faucet
mounted in
- )le in existing hc
sink.
Cold water line
30” max.-electrical
outlet to hot water
dispenser tank.
sink or countertop
hole