KitchenAid 3186508 Cooktop User Manual


 
Electronic Ignition System -
initial lighting and gas flame adjustments.
Cooktop burners use electronic ignitors in place
of standing pilots. When the cooktop control
knob is turned to the “HI” position, the system
creates a spark to light the burner. This sparking
continues until the burner has a flame.
115.1
HI
Check the operation of the cooktop
burners. Push in and turn each
control knob to the “HI” position. The flame
should light within 4 seconds.
Check each cooktop burner for
proper flame. The small inner cone
should have a very distinct blue flame
approximately l/2” long. The outer cone is not
as distinct as the inner cone. The “LO” (or
simmer) setting of each burner has been factory
set to the lowest setting available to provide
reliable reignition of the burner. If any burner
does not stay lit on the “Lo” setting, contact
your KitchenAid dealer for assistance.
1171
. If burners do not light properly, turn
cooktop control knob to the “OFF”
position. Check that burner cap is in proper
position. Check the power to the unit and the
circuit breaker or house fuse. Check that gas
valves are set to the “ON” position. Repeat Step
16. If a burner does not light at this point,
contact a KitchenAid dealer for assistance.
(181
. Refer to your “Use and Care Guide”
and check the ooeration of the oven
bake element and broil element.
L.P. gas conversion
No attempt shall be made to convert the
appliance from the specified gas on the rating
plate for use with a different gas without
consulting the serving gas supplier. Conversion
to L.P. gas requires Kit No. 4175461 available
from your KitchenAid dealer. This conversion
must be done by a qualified technician. Contact
your KitchenAid dealer.
Panel E