Connect the yellow/green earth wire to the terminal with the symbol .
This wire must be longer than the other wires.
1. Remove the terminal block cover (A), undoing the screw and inserting the cover in the terminal block
hinge (B).
2. Strip approx. 70 mm of sheath from the power supply cable.
3. Strip approx. 10 mm of sheath from the wires. Insert the power supply cable into the cable clamp and
connect the wires to the terminal board as indicated in the diagram next to the terminal board itself.
4. Secure the power cable with the cable clamp.
5. Close the cover (C) and screw it on the terminal block with the removed screw - point (1).
Repeat the same procedure for the second terminal board.
Each time the cooktop is connected to the mains it carries out an automatic check which lasts several
seconds.
Connect the appliance to the mains electricity supply using a multipole switch disconnector with minimum
contact gap of 3 mm.
CBA
Conductors Amount x size
230 V ~ +
3 x 4 mm
2
230-240 V ~ +
3 x 4 mm
2
(Australia only)
230 V 3 ~ +
4 x 1,5 mm
2
400 V 3N ~ +
5 x 1,5 mm
2
400 V 2N ~ +
4 x 1,5 mm
2
400 V 3N ~ 230 V ~ 230-240 V ~ (Australia only)
230 V ~ (UK only)
400 V 2N ~ 230 V 3 ~
(Belgium only)
400 V 2N ~
(NL only)
Electrical connection
If the hob does not have power supply cables provided, for electrical connection, use two H05RR-F type
cables (to be connected to the two terminal boards) as indicated in the table below.