KitchenAid KHMS 106 Microwave Oven User Manual


 
t.
RECIRCULATING: Non-Vented, Ductless
I. Remove and save 9 screws. Remove rear stay.
(Fig. 5
pg. 11).
2.
Withdraw hood fan unit.
(Fig. 6
pg. 11).
3.
Change lead wire holding position from left side wire
retainer to right side wire retainer
(Fig. 11).
4.
Rotate hood fan unit so exhaust opening faces in, to-
wards the upper side of the oven.
Replace hood fan unit into oven unit by pressing it as
shown
(Fig. 12).
Be careful that back plate and hood fan unit do not pinch
lead wire.
5.
Replace rear stay.
First, attach rear stay to unit with 2 screws
(Fig. 9
pg. 12).
Safety Screw is located on the rear stay to prevent im-
proper installation. Do not remove this screw. If you
cannot attach rear stay to the back plate precisely, the
hood fan unit is improperly placed and the safety screw
will not line up. Check steps 3 & 4 again.
6.
Secure using remaining 7 screws
(Fig. 10
pg. 12).
Figure 11
Figure 12
NOTE: Backdraft Damper is not required for recirculating exhaust. It is recommended that the Backdraft
Damper be saved should outside venting be decided upon at a later time.
13