KitchenAid KPID850T Ventilation Hood User Manual


 
Dimensions for 30” and 36” downdraft vent
systems when installed with a KitchenAid
cooktop:
Before you start...
Proper lnslallatlon IS the Installer’s responslblllly.
A quaIlfled technician should ~nslall Ihis downdraft “en!
system Make sura you have everything necessary lor
corred ~nslallal~on II IS Ihe responslblllly 01 Ihe
mstaller lo comply with Ihe installallon clearances
specllled ,n these ~nslrucl~ons.
Check locatlon where downdrall venl and cooklop WIII
be inslalled. The local~on should be away from slrong
drall areas, such as windows or doors and strong
healing ven,s or lans.
Eleclrlcal ground is requred See Eleclr~cal
requiremenls
If cablnel hss a drawer, Ihe drawer WIII need lo be
removed and Ihe drawer lronls lnslalled permanently lo
lronl of cabfnel
Counlerlop openlna dlmenslons lhal are shown
Built-in cabinet dimensions:
y1” *sn, YI” -
36” base cablnel IS recommended lor Ihe
30’downdrafl “en,.
42” be% cablnel IS recommended lor Ihe
36- downdrafl “en,
Note: The downdraft “en, IS located dlrealy behmd
the cookiop lnslall downdraH “en, hrsl
Important: Observe all governing
1 ;;;,I; Ordinances’
ALL OPENINGS IN THE WALL OR FLOOR WHERE
Failure to meet codes and ordinances
THE DOWNDRAFT VENT IS TO BE INSTALLED
e
could lead to fire or electrical shock
1 \l
downdraft vend before using the
Island cabinet dimensions:
30’ CtiO”! Widlh ZT
NOTE:
It is the customer’s
responsibility to:
- contact a qualified, electrical
installer.
- assure that electrical
installation is adequate and in
conformance with National
Electrical Code, ANSVNFPA
70-1987” and local ordinances.
8 7,v
----------I
FOR YOUR SAFETY:
Special care must be taken when
drilling holes into the wall.
Electrical wires may be
concealed behind wall covering.
Use dimensions lor vent duct locatlon
lhal apply lo your Inslallatlon. Diameler
of cut-out will be delermlned by Inslallallon.
J
I
I
Tools and materials
Downdraft vent dimensions:
Mobile Home Installation
The mslaHa11on of IhIs downdraH vanI mus! conlorm lo
Ihe Manufactured Home Conslrucl~on and Salely
Slandarda. TII!B 24 CFR. Parl 3280 (formerly the
Federal Standard for MoblIe Home Conslruct~on a-d
Salely T~!le 24. HUD, parI 280) Four-wre power
supply musl be Jsed and Ihe appliance Waring mu51 Se
,evlsed See E~eclr~cal reqwemenls
Capes 01 ,hs standards l,sled may be ablalned :‘o-,
** National Fire Proleclion Associalion
II,
See cooktop Installation
lnstructlons for
I
cooktop dimensions,
PANEI- A
I
Ballery March Park
O”,ncy. hlassachusells 02169