KitchenAid KUIS15NRH Ice Maker User Manual


 
5-3
WATER RECIRCULATION PUMP
Refer to page 4-7 for the procedure for servic-
ing the water recirculation pump.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the R x 100 scale.
3. Touch the ohmmeter test leads to the
outside water recirculation pump wire con-
nector pins. The meter should indicate
between 17 and 23 .
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Refer to page 4-8 for the procedure for servic-
ing the condenser fan motor.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads to the
outside pins of the condenser fan motor
connector. The meter should indicate be-
tween 265 and 285 .
CONDENSER FAN MOTOR