KitchenAid KWC-200 Garbage Disposal User Manual


 
ELECTRICAL INSTALLATION INSTRUCTIONS:
(115 Volt, 60 Hertz)
I
Follow your electrical code in all details. In
older houses with limited circuits, or if it
appears the circuit is heavily loaded, run a line
directly to the main fuse box.
1. Remove the electrical access cover on the
bearing bracket assembly.
2. Install standard connector (not furnished)
into threaded opening in bearing bracket
assembly.
3. Install an operating control switch where
it is easily accessMe, for the owner.
Recommended: On-Off switch suitable
for operation of l/2 H.P. motor. (Switch
not furnished.)
‘4. Run flexible conduit, or equivalent, from
the control switch to the electrical power
supply. Insulate all connections.
5. Run flexible conduit, or equivalent, from
the control switch to the disposer motor
leads located in the bearing bracket assem-
bly. Connect unit to ground. (See illustra-
tion).
6. Press wires into the electrical access com-
partment and replace cover.
NOTE:
Follow your local electrical code in all
details. In older houses with limited circuits,
or if it appears the circuit is heavily loaded,
run a line directly to the main fuse box.
GREEN LEAD
TWIST. SOLDER &
TO GROUND
INSULATE BOTH
CONNECTION
CONNECTIONS
/
MANUALLY
OPERATED RESET
BUTTON. PUSH
TO RESET IF
MOTOR STOPS
ONOVERLOAD
OR JAM,