To Convert Grill Burner (on some models)
1. Remove grill grate, wave plate, flame spreader and burner
assembly. See “Install Grill Grease Trays” section for removal
instructions. Set parts aside.
2. Use a ½" deep-well socket and remove the LP gas orifice
hood. Replace with correct grill Natural gas orifice hood. See
“Natural Gas Orifice Spud/Hood Chart.”
3. Turn Natural gas orifice hood down tightly onto orifice base.
4. Place LP gas orifice hoods in plastic parts bag for future use
and keep with package containing literature.
5. Open shutoff valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
REMEMBER: Once you have completed converting the grill,
test the cooktop for leaks by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show,
indicating a leak. Correct any leaks found.
6. Plug in cooktop or reconnect power.
Complete Installation
1. Refer to the “Make Gas Connection” section for properly
connecting the cooktop to the gas supply.
2. Refer to the “Electronic Ignition System” section in the
“Complete Installation” section for proper burner ignition,
operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the “LO” setting for
each cooktop burner.
Checking for proper cooktop burner flame is very important.
The small inner cone should have a very distinct blue flame
¼" (0.64 cm) to ½" (1.3 cm) long. The outer cone is not as
distinct as the inner cone. LP gas flames have a slightly
yellow tip.
3. Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
STRIP CIRCUITS
Griddle 120V Control Wiring Diagram To Cooktop Stand-Alone
Grill Reignition Wiring Diagram To Cooktop Stand-Alone and Freestanding
A. Grill orifice hood location
A
R
W OR/W
OR/W OR/W
W
V
W
VVWW
P2-1
P2-6
P1-1
P1-3
P1-4
P1-6
Rotary Control
RTD
BU W
1320W/120V
Lamp 120V
BK
BR BR
Reignition Module
Lamp 120V
W
W
BU