2. Attach terminal lugs (located in the package containing
literature) to line 1 (black), bare (green) ground, and line 2 (red)
wires. Loosen (do not remove) the setscrew on the front of
the terminal lug and insert exposed wire end through bottom
of terminal lugs. Securely tighten setscrew to
XX lbs-in. torque. See Bare Wire Torque Specifications chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use ³⁄₈" nut driver to connect the bare (green) ground terminal
lug to the center terminal block post with one of the 10-32
hex nuts.
4. Connect line 1 (black) and line 2 (red) terminal lugs to the
outer terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Make Gas Connection
Typical flexible connection
1. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a ¹⁵⁄₁₆" combination wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
4. Gas supply pipe must be located within clearance area as
shown in the “Cabinet Dimensions” illustration in “Location
Requirements” section.
A.Terminal lug
B.Setscrew
C.Line 1 (black) wire
D.Bare (green) ground wire
E.Line 2 (red) wire
Wire Awg Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum 35 lbs-in. (4.0 N-m)
A.10-32 hex nut
B.Line 1 (black)
C.Ground-link screw
D.Bare (green) ground wire
E.Line 2 (red)
F. Terminal lug
A
B
C
DE
B
F
A
E
D
C
A.Gas pressure regulator
B.Use pipe-joint compound.
C.Adapter (must have ½" male
pipe thread)
D.Flexible connector
E.Manual gas shutoff valve
F. ½" or ¾" gas pipe
G.Use pipe-joint compound.
H.Adapter
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.