KitchenAid W10526086A Double Oven User Manual


 
19
Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Locate gas pressure regulator at the rear of the range.
IMPORTANT: Do not remove the gas pressure regulator.
2. Unscrew the regulator cap and remove the plastic cover.
3. Flip the regulator cap over and replace the plastic cover.
4. Screw the regulator cap securely back into place. Do not
overtighten.
To Convert Surface Burners
1. If the burner grates are installed, remove them.
2. Remove the burner caps.
3. Using a Phillips or T20
®
Torx
®†
screwdriver, remove the burner
base.
A.To range
B.Shutoff valve (closed position)
C.Gas supply line
A.Gas pressure regulator
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A
A.Plastic cover
B.Regulator cap
A.LP gas position
B.Natural gas position
C.Plastic cover
A.Burner cap
B.Gas tube opening
C.Burner base screws
D.Burner base
A
B
A
B
C
A
B
C
D