Kobe Range Hoods CH0042SQB (42") Ventilation Hood User Manual


 
10
mark the leveling point of the hood. Position two
mounting screws (not included) on the wall,
leaving 1/8” away from the wall. Refer to Figure 13
2. Align hood-mounting bracket to the two screws
on the wall and hook hood into place. Tighten
screws to secure hood to the wall.
3. For safety purpose, pre-drilled mounting holes
are provided through the back of the hood. For a
more secure installation, use as many mounting
holes as needed to secure from the inside of
hood (screws not included).
CAUTION: MAKE SURE HOOD IS SECURE
BEFORE RELEASING.
WALL
Figure 13
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE
HOOD MUST BE PROPERLY GROUNDED. MAKE
SURE THIS IS DONE BY QUALIFIED ELECTRICIAN
IN ACCORDANCE WITH ALL APPLICABLE
NATIONAL AND LOCAL ELECTRICAL CODES.
BEFORE CONNECTING WIRES, SWITCH POWER
OFF AT SERVICE PANEL AND LOCK SERVICE
PANEL TO PREVENT POWER FROM BEING
SWITCHED ON ACCIDENTALLY.
4. Connect the electrical wires.
- Connect three wires (black, white and green)
to house wires and cap with wire connectors.
Connect according to color: black to black,
white to white, and green to green as shown
in Figure 14.
- Store wires in the wiring box.
Figure 14