Kobe Range Hoods CH8036SQ Ventilation Hood User Manual


 
6
{Fig. 4}
3) Repeat installation instruction from previous step 5).
Making The Electrical Connection (Should Be Done By A Licensed Professional)
----SAFETY WARNING----
INTERIOR OF HOOD MAY HAVE VERY SHARP EDGES; PLEASE
WEAR PROTECTIVE GLOVES IF THE BOTTOM CASING NEEDS
TO BE REMOVED FOR CLEANING OR SERVICING.
(Neutral) (Black)
(blue) (Ground) (brown)
(yellow/green)
1) There are three different color wire strands to be connected. Strip solid wire 5/16” and strip
stranded wire 3/8”.
2) Connect the power line ground wire to the grounding green lead supplied with the hood.
Ground wire will always be green.
3) Make the electrical connections by fastening the brown power wire to the opposing black
power wire and the hood’s blue power wire to the other white wire. Align any frayed strands
or conductors. Screw on conductors; push wires firmly into connectors when starting. Stop
when the bottom of the connector reaches conductor. Follow all electrical safety codes.
4) Plug into electrical outlet. Turn on power and check operation of fans and light.
5) Check that your fuse has not worked its way loose in shipping. Please see section on
Changing the Fuse.
Congratulations, your KOBE range hood is ready to be used!