Kobe Range Hoods RA3830SQD Ventilation Hood User Manual


 
6
4. Draw electrical wires through cabinet access opening.
5. Place screws (not provided) into the exact center of each knockout hole. Make sure all
screws are in place before tightening screws. CAUTION: MAKE SURE THE HOOD IS
SECURE BEFORE RELEASING.
6. Connect the electrical wires. Refer to “Wiring to Power Supply.” If necessary to hide the
electrical wire connections, push wires back into the wiring box. Access the wire
connections underneath the hood by removing the bottom casing from the six screws.
Before reattaching the bottom casing, make sure wires do not slip between motors,
impellers, or any moving parts to prevent any damage. NOTE: Be careful when using
electrical screwdriver, damage to the hood may occur.
Wiring to Power Supply
S AF ET Y W A R N IN G
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
- Connect three wires (black, white and green) to house wires and cap with wire connectors.
- Connect according to color: black to black, white to white, and green to green.
- Test the operation of the hood before moving on to next step. Make sure power is supplied
to the hood.
Final Assembly
7. Turn power ON in control panel. Check all lights and fan operation.
8. Make sure to leave this manual for the homeowner.