Kramer Electronics t Ventilation Hood User Manual


 
Install the Kramer RK-1UTB/T Under the Table Enclosure
7
5.1.2 Mounting a Kramer Machine
The RK-1UTB/T underside mounting area includes a set of screw holes that
are suitable for any combination of units to be mounted.
To mount a unit on the RK-1UTB/T (for example, the Kramer TP-953
MultiTOOL
1
Figure 2), as illustrated in , do the following:
1. Place the TP-953 on the rack.
2. Hold both the TP-953 and the RK-1UTB/T with your hands and turn
them upside down.
3. Insert the appropriate amount of screws
2
Figure 6
through the holes on the
RK-1UTB/T that fit the holes on the underside of the TP-953, using the
M3x6 screws supplied with the unit (as illustrated in ).
4. Tighten the screws.
5. Rotate the RK-1UTB/T horizontally with the unit connected
3
.
Figure 6: RK-1UTB/T Under the Table EnclosureUnderside
To mount a second 1/4U unit or, alternatively, a 1/2U unit, repeat the above
procedure
4
1 A 1/4U machine
.
2 In this example, 3 screws are used to mount the TP-953
3 When connecting several units (as defined in
Table 1), place the next unit and then repeat steps 2 to 5
4 A 1/2U unit will require a different number of screws. To mount a 1/2U unit with no underside screw holes, see section
5.4