Kuppersbusch USA GMS 6540.0 E-UL Food Warmer User Manual


 
INSTALLATION
8
6) ROOM VENTILATION
To ensure correct operation of the appliance, it is
important to ensure that the room where the hot
plate is installed has sufficient ventilation.
7) GAS CONNECTION
Natural Gas and Propane Gas
Natural Gas installations require the connection of
a gas regulator at the appliance. This regulator is
supplied with the appliance on purchase.
Assemble the regulator (noting the gas flow
direction) and transition pieces (supplied with the
appliance), in accordance with below figure.
The transition piece on the supply side of the
regulator must be provided by the installer.
Unions compatible with the hose fittings must be
used and connections tested for gas leaks.
Ensure the supply connection point is accessible
with the appliance installed.
Warning: ensure that the hose assembly is
restrained from accidental contact with the flue or
flue outlet of an underbench oven.