![](http://pdfasset.owneriq.net/c/f9/cf9537bc-6f4e-4dd3-98a4-0d7db33debd8/cf9537bc-6f4e-4dd3-98a4-0d7db33debd8-bg13.png)
7-8
D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove vertgrille.
(2) Remove mount all.
(3) Remove outcase.
(4) Discinnect the wireleads.
(5) Remove the 3 screws and Magnetron very
carefully.
NOTE:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
• After replacing the magnetron, check for microwave
energy leakage with a survey meter Check
microwave energy leakage must be below the limit
of 5 mW/cm
2
. (All service adjustments should be
made for minimum microwave energy leakage
readings.)
Figure 11
Figure 13
Figure 12
vertgrille
mount all
Magnetron
outcase