Liebherr 290910 7084364 - 03 Refrigerator User Manual


 
4.2 Insertion into a row of kitchen units
Fig. 9
(1) Stack cabinet (3) Kitchen cabinet
(2) Appliance (4) Wall
The appliance can be inserted into a row of kitchen units. To
match the appliance
Fig. 9 (2)
to the height of the row of units,
a suitable stack cabinet
Fig. 9 (1)
can be fitted above the appli-
ance.
When inserting the appliance into a row of kitchen units (max.
depth 580 mm), the appliance can be installed directly next to
the kitchen unit
Fig. 9 (3)
. The appliance door projects relative
to the front of the kitchen unit by 34 mm at the side and by
50 mm in the middle of the appliance. It can be opened and
closed perfectly as a result.
Important for the ventilation:
-
At the back of the stack cabinet there has to be a ventilation
duct of at least 50 mm depth throughout the width of the
stack cabinet.
-
The ventilation space under the ceiling has to be at least
300 cm
2
.
-
The larger the ventilation space, the more energy-saving the
appliance is in operation.
If the appliance is installed with the hinges next to a wall
Fig. 9 (4)
, the distance between appliance and wall has to be at
least 40 mm. This corresponds to the projection of the handle
when the door is open.
4.3 Transporting the appliance
CAUTION
Risk of injury and danger of damage as a result of incorrect
transport!
u
Transport the appliance in a packed condition.
u
Transport the appliance upright.
u
Do not transport the appliance without assistance.
4.4 Installing the appliance
In the event that the appliance is damaged, contact the supplier
immediately before connecting to the mains.
The floor at the site must be flat and level.
Do not install the appliance in a location where it is exposed to
direct radiation of the sun, next to a cooker, heater and similar.
Always install the appliance with the back directly against the
wall.
Do not install the appliance without assistance.
Standard EN 378 specifies that the room in which you install
your appliance must have a volume of 1 m
2
per 8 g of R 600a
refrigerant used in the appliance. If the room in which the appli-
ance is installed is too small, a flammable gas-air mixture may
form in the event of a leakage in the refrigeration circuit. The
quantity of refrigerant used in your appliance is indicated on the
type plate on the inside of the appliance.
The appliance may be moved only when it is empty.
WARNING
Fire hazard due to dampness!
If live parts or the mains lead become damp this may cause
short circuits.
u
The appliance is designed for use in enclosed areas. Do not
operate the appliance outdoors or in areas where it is
exposed to splash water or damp conditions.
WARNING
Fire hazard due to refrigerant!
The refrigerant R 600a is environmentally friendly but flam-
mable. Escaping refrigerant may ignite.
u
Do not damage the piping of the refrigeration circuit.
WARNING
Fire hazard and danger of damage!
u
Do not place appliances emitting heat e.g. microwaves,
toasters etc. on the appliance!
WARNING
Blocked ventilation openings pose a risk of fire and damage!
u
Always keep the ventilation openings clear. Always ensure
that the appliance is properly ventilated!
u
Detach the connecting cable from the rear of the appliance,
removing the cable holder at the same time because other-
wise there will be vibratory noise!
u
Remove the protective film from the outside of the appli-
ance.*
NOTICE*
The stainless steel doors are provided with a high-quality
surface coating and must not be treated using the accompa-
nying care product.
Otherwise the surface coating will be affected.
u
Wipe the coated door surfaces using a soft, clean cloth
only.
u
Apply a stainless steel cleaner only to the stainless steel
side walls evenly, wiping with the grain. Subsequent
cleaning becomes easier as a result.
u
Wipe side walls with a paint finish using a soft, clean
cloth only.
Putting into operation