Liebherr FV3613 Freezer User Manual


 
Setting up
Do not place the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
The floor on which the appliance stands should be hori-
zontal and level. Compensate for uneven floors with the
adjustable feet.
There must be a gap of at least 20 cm between the upper edge
of the appliance and the ceiling.
Do not cover ventilation ope-
nings or grille.
Standard EN 378 specifies
that the room in which you install your
appliance must have a volume of 1 m
3
per 8 g of R 600a (R 290) refrigerant
used in the appliance, so as to avoid
the formation of inflammable gas/
air mixtures in the room where the
appliance is located in the event of a leak in the refrigerant
circuit. The quantity of refrigerant used in your appliance is
indicated on the type plate on the inside of the appliance.
Always install the appliance directly against the wall .
Appliance dimensions
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the
type plate. The position of the type plate is shown in the section
entitled Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16
A.
The socket must not be situated behind the appliance
and must be easily accessible.
Do not connect the appliance using an
extension cable or extension socket.
Do not use stand-alone inverters (conver-
sion of direct current to alternating current/
threephase current) or energy-saving plugs.
Risk of damage to the electronic control
system!
Safety lock
The lock is equipped with a safety mechanism.
Locking the appliance
Insert the key as shown by
arrow 1.
Turn the key 90°.
To unlock the appliance, the
same procedure must be re-
peated in the same order.
GB