Liebherr HC1011 Refrigerator User Manual


 
after switch-on the temperature is not yet cold enough
the temperature has risen by several degrees
Dashes are shown on the display:
the freezer temperature is above 32 °F (0 °C).
The following displays indicate malfunction. Possible cau-
ses and corrective actions are to be found in the Trouble-
shooting section.
nA
F0 bis F5
4 Start-up
4.1 Transporting the appliance
CAUTION
Risk of injury or damage if incorrectly transported.
u
Transport the appliance in its packaging.
u
Transport the appliance upright:
u
Do not move the appliance on your own:
4.2 Setting up the appliance
WARNING
Risk of fire due to moisture!
If live parts or the power cord get wet, this can cause a short
circuit.
u
The appliance is designed for use in enclosed spaces.
Do not operate the appliance in open space or in damp
areas or where there is spray.
WARNING
Danger of fire and damage!
u
Do not place devices that give off heat, e.g. microwaves,
toasters, etc. on the appliance.
CAUTION
Risk of personal injury!
u
Have two people move this appliance into place.
NOTICE
Risk of damage caused by condensation
Installing the appliance next to any other refrigerator or
freezer can cause damage or condensation to the Liebherr
appliance.
u
Do not install this appliance next to any other refrigerator
or freezer except another Liebherr model. Liebherr mod-
els are designed to allow side-by-side installation. They
are equipped with a heating system to eliminate conden-
sation when refrigerators or freezers are installed side-
by-side.
NOTICE
Risk of damage for the finished floor surface!
u
Protect the finished floor surface before you uncrate the
unit.
Verify that:
q
the floor under the appliance is flat and level.
q
the floor can support the appliance's weight plus approx-
imately 1200 pounds (544 kg) of food weight.
q
the appliance is not placed in direct sunlight or near the
stove, range top, radiators and similar heat sources.
q
the kitchen cabinet that the appliance is installed in is
shimmed to the floor level if the floor heights are not
equal.
q
cutout dimensions are accurate.
q
electrical outlet is in correct location.
q
the air flow is not restricted. Air flow must be provided for
the appliance to operate properly. The factory air vents
provide 31 square inches (200 cm
2
) of air flow per appli-
ance. If you are replacing the air vents with an overlay,
the air flow must be the same or greater than the factory
air vents.
u
Examine the unit and packaging for shipping damage.
Contact the carrier immediately if you suspect there is
any damage.
u
Note the type (model, number), index, appliance/serial
number, date of purchase and where purchased on the
spaces provided in see Appliance Information.
u
Remove anything attached to the rear or side walls of
appliance that would prevent proper installation or im-
pede proper ventilation.
If the appliance is set up in humid areas, condensation may
build on the outside of the appliance.
u
Always ensure proper ventilation.
4.3 Disposal of packaging
WARNING
Danger of suffocation from packaging materials and films!
u
Do not allow children to play with packaging materials.
The packaging is made from recyclable materials:
Corrugated card/cardboard
Preformed pieces from foamed polystyrene
Films and bags from polyethylene
Packing bands from polypropylene
u
Take the packaging material to an official collection point.