Liebherr LGex 910 Freezer User Manual


 
20
The condenser must be unscrewed
to make the sensor cable opening
accessible.
1. Unscrew condenser screws
(6 pcs.) and fold out condenser
at an angle.
Important!
Make sure that no pipes are bent.
Opening for external temperature sensor
Model LGex 3410
Remove upper drawer before beginning work.
2. Drill marked section at the back of
appliance.
3. Pull out strain relief device (top left
of interior container).
4. Feed sensor through opening
and secure sensor cable with
strain relief device.
Important!
Position the sensor at the top of the interior container. The sen-
sor must not come into contact with objects so that only the air
temperature is measured.
Important!
5. Close the sensor cable opening
at the back of the appliance with
the sealant provided.
6. Screw condenser back on.
Important!
Only drill the outer wall of the
housing.
Do not drill too far.
1. Drill marked section on the back of
the appliance.
Opening for external temperature sensor
Model LGUex 1500
2. Pull out strain relief device (bot-
tom left of interior container).
3. Feed sensor through opening and
secure sensor cable with strain
relief device.
Important!
Position the sensor at the top of the interior container. The sen-
sor must not come into contact with objects so that only the air
temperature is measured.
Important!
4. Close the sensor cable opening at the back of
the appliance with the sealant provided.