Liebherr LGex 910 Freezer User Manual


 
12
Adjustable-height feet
Description of appliance and equipment
Type plate
Operating and control
elements
Disposal notes
Keep packaging materials away from children - polythene
sheets and bags can cause suffocation!
• Please return the packaging to an official collection point.
Your old appliance: This contains some reusable materials
and should be disposed of properly - not simply with unsorted
household refuse.
• Discarded appliances should be disabled: Remove the
plug, cut through the connection cable and render the
catch unusable so that children cannot become trapped
inside.
• Ensure that the refrigerant circuit is not damaged when
the appliance that is no longer needed is taken away
for disposal.
• Details of the refrigerant can be found on the type plate.
• Appliances which are no longer needed must be disposed of in a
professional and appropriate way, in accordance with the current
local regulations and laws.
Drawers
Safety instructions and warnings
• To prevent injury or damage to the unit, the appliance should be
unpacked and set up by two people.
• In the event that the appliance is damaged on delivery, contact
the supplier immediately before connecting to the mains.
• To guarantee safe operation, ensure that the appliance is set up
and connected as described in these operating instructions.
• Disconnect the appliance from the mains if any fault occurs. Pull
out the plug, switch o or remove the fuse.
• When disconnecting the appliance, pull on the plug, not on the
cable.
• Any repairs and work on the appliance should only be carried
out by the customer service department, as unauthor ised work
could prove highly dangerous for the user. The same applies to
changing the mains power cable.
• Do not stand on the plinth, drawers or doors or use them to sup-
port anything else.
• This appliance is not intended for use by persons (including chil-
dren) with reduced physical, sensory or mental capabilities or lack
of experience and knowledge unless they have been given initial
supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
• Avoid prolonged skin contact with cold surfaces or chilled/frozen
food. This could cause pain, numbness and frostbite. In the case
of prolonged skin contact, protective measures should be taken,
e.g. gloves should be worn.
• Do not consume food which has been stored for too long, as it
could cause food poisoning.
• If you have a lockable appliance, do not keep the key near the
appliance or within reach of children.
• Do not allow naked ames or ignition sources to enter the appli-
ance. When transporting and cleaning the appliance ensure that
the refrigerant circuit is not damaged. In the event of damage,
make sure that there are no ignition sources nearby and keep the
room well ventilated.
• Do not use electrical appliances inside the appliance.
• Do not connect the appliance to the supply with other equipment
using an extension cable. This can cause the extension socket to
overheat.
• Do not install the appliance in the immediate vicinity of an air-
conditioning unit. The appliance should also not be operated
under a wall-mounted air-conditioning unit.
• The appliance is not suitable for storing drugs pursuant to
DIN 58345.
• The appliance is not suitable for storing blood bottles pursuant
to DIN 58371.
• The appliance is not suitable for storing blood plasma pursuant
to DIN 58375.
• In special elds of application which are subject to their own
standard, the user is responsible for complying with this standard.
• The appliance is designed for use in enclosed areas. Do not
operate the appliance outdoors or in areas where it is exposed
to splash water or damp conditions.
Opening for external tem-
perature sensor.
On model LGex 3410, this
opening is located in the top
part of the appliance.
Other features
- Audible and visual temperature alarm (adjustable limits).
- Audible and visual door open alarm.
- Floating contact for connection to a remote monitoring system.
- Serial interface (RS485) for external temperature and alarm
documentation.
- Maximum/minimum interior temperature are stored.
- Last 3 temperature alarms are saved with time, date and duration
of alarm.
- Last 3 power cuts are saved with time, date and duration of power
cut.
- Opening for installing a reference sensor.
It is essential to use these safety facilities to avoid damage
to stored items. These facilities must not be deactivated or
decommissioned!