PLACE DIGITAL VOLTMETER LEADS ON terminal S1 and S2, adjust the max pot. for a
reading of 3.4 VDC.
Place METER LEADS on terminals A1 and A2. Adjust the reg. pot. for a reading of 125 VDC.
NOTE: In some instances when the input AC voltage runs on the high side of the normal
input range, you may have difficulty adjusting the max. pot. for a reading of 3.4 VDC. In this
instance, a reading of 3.45 VDC is acceptable.
Adjust speed pot to obtain the proper time setting for the conveyor to meet customers desired
speed .
Check conveyor travel in a no load situation to insure conveyor belt is traveling at a constant
speed.