L25-001 REV 1 (11/02)
RMB 600 Series -S Models with safety pilot
1. Turn all burners to OFF.
2. Remove the top grid.
3. Remove a radiant.
4. Turn the shut off valve to ON.
5. Press and hold the reset (blue) button on the safety pilot valve. Wait 15–30 seconds. Light the runner
tube. DO NOT release the reset button.
NOTE: If the runner tube does not light, wait a few seconds, then try again.
NOTE: When lighting the runner tube for the first time after connecting the unit to the gas source, the light
time will probably increase to 1–2 minutes.
6. Wait an additional 15–30 seconds. Release the reset button. The runner tube should remain lit.
NOTE: If the runner tube fails to ignite, repeat step 5. If the runner tube fails to ignite after three
attempts, contact an authorized MagiKitch’n service agent.
7. Replace the radiant and top grid.
8. Push and turn the burner valves to operate the individual burners as needed.
Broiler Shut Down
1. Turn the shut off valve to OFF.
2. Turn all burners to OFF.
Off
On
Shut-off
Valve
Safety Pilot Valve
(located under
shelf)
Thermocouple
(located on far
end of runner tube)
Top Grid
Radiant
Reset Button
Safety Pilot Valve
Runner Tube
SMB 600 Series -S Models with safety pilot
Lighting and shut down of these models is identical to that of the RMB-S models except that there
are no radiants to be removed. Simply light the runner tube by inserting the ignition device through
the gap between the front burner support and the coal support as shown in the lighting instructions
for the SMB 600 Series Models without safety pilot.