Manitowoc Ice Q130 Ice Maker User Manual


 
Section 4 Maintenance
Part Number 000001130 12/08 4-3
Q130 Models
Q130 Water Distribution Tube Removal
Loosen the two thumbscrews, which secure the
distribution tube.
Lift the distribution tube up off the thumbscrews.
Disassembly
Twist the barbed end until the tab lines up with the
keyway.
Pull the inner tube end outward.
Q130 Water Distribution Tube Disassembly
E. Remove the Float Valve
Turn the splash shield counterclockwise one or two
turns.
Float Valve Removal
Pull the float valve forward and off the mounting
bracket.
Disconnect the water inlet tube from the float valve at
the compression fitting.
Remove the cap and filter screen for cleaning.
THUMBSCREW
REMOVE ICE
THICKNESS PROBE
THUMBSCREW
DISTRIBUTION
TUBE
TAB
KEYWAY
FLOAT VALVE
BRACKET
COMPRESSION
FITTING
CAP AND
FILTER SCREEN
SHUT-OFF VALVE
SPLASH SHIELD
FLOAT