Water and Drain Requirements
POTABLE WATER REQUIREMENTS
Follow these guidelines to install water inlet lines:
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
If water pressure exceeds the maximum of 80 psig
(552 kPA) recommended pressure, obtain a water
pressure regulator from your Manitowoc distributor.
Install a water shut-off valve and union for both the
ice making and condenser water lines.
Insulate water inlet lines to prevent condensation.
Plumbing must conform to local codes.
WATER SUPPLY AND DRAIN LINE SIZING/
CONNECTIONS
Typical Water Supply Drain Installation
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to prevent
drain water from flowing back into the ice machine and storage
bin:
Drain lines must have a 1.5 inch drop per 5 feet of run (2.5
cm per meter), and must not create traps.
The floor drain must be large enough to accommodate
drainage from all drains.
Run separate bin and water-cooled condenser drain lines.
Insulate them to prevent condensation.
Vent the bin and ice machine drain to the atmosphere. The
ice machine drain requires an 18" (46 cm) vent. Do not
vent the condenser drain on water-cooled models.
Drains must have a union or other suitable means to allow
in place disconnection from the ice machine when
servicing is required.
Location
Water Temp
Min/Max
Water
Pressure
Min/Max
Fitting/Min
Tubing
Size
Potable
Water Inlet
40°/90°F
(4°/32°C)
14/80 psi
(100/552 kPA)
3/8" FPT
Potable
Water Drain
--- --- 1/2" MPT
Condenser
Water Inlet
40°/90°F
(4°/32°C)
20/150 psi
(138/1034 kPA)
3/8” FPT
RF2300 only
= 1/2" FPT
Condenser
Water Drain
--- --- 1/2" MPT
Bin Drain --- --- 3/4" FPT
Large Capacity Bin Drain --- 1" FPT
VENT TUBE
18" (46 CM)
LONG
ROUTE
DRAIN
TUBING TO
OPEN SITE
DRAIN
ICE MAKING
WATER INLET
TUBING 3/8" MIN.
I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
SEPERATE BIN AND ICE
MACHINE DRAINS ARE
REQUIRED
ROUTE DRAIN TUBING TO
OPEN SITE DRAIN
WATER SHUT-OFF VALVE
REQUIRED - ICE MAKING
WATER INLET TUBING 3/8"
MIN. I.D. (.95 CM)