28
BASIC
(6 different control scenarios to be tested)
11.1 MAIN CONTROLS
This procedure allows the installer to verify that all modes of operation are fully functional.
During the verification of a main control, make sure that all optional remote controls are inactive.
11.0
Overall Verification
Set the slider Set condensation control Results expected
switch to dial to fan speed
1 Off maximum counterclockwise motor off
2 Off maximum clockwise motor off
3 Min. maximum counterclockwise low speed
4 Min. maximum clockwise high speed
5 Max. maximum counterclockwise high speed
6 Max. maximum clockwise high speed
CO
NDEN
S
AT
I
0
N
CO
NTR
O
L
AIR SUPPL
Y CONTRO
L
L
L
MIN.
MAX.
O
F
F
A
AI
R
R
I
I
EXCHANGE
CH
HA
-2
0
C
-
4
°
41
°
F
C
O
F
Z
N
E
S
U
M
M
E
R
VC0027
Set air supply Set condensation control
Results expected
control to dial to
Fan Exchange Max speed
speed indicator indicator
(A) (B)
1 Off maximum counterclockwise off off off
2 Off maximum clockwise off off off
3 Min. maximum counterclockwise low on off
4 Min. maximum clockwise high on on
5 Max. maximum counterclockwise high on off
6 Max. maximum clockwise high on on
7 Intermittent maximum counterclockwise
off 40 min off 40 min off
low 20 min on 20 min off
8 Intermittent maximum clockwise high on on
ELECTRONIC (8 different control scenarios to be tested)
°
C
-
4
°
F
-
5
C
41
°
F
CO
NDEN
S
AT
I
0
N
CO
NTR
O
L
AIR SUPPL
Y CONTRO
L
L
L
CO
NDEN
SA
T
I
O
N
CO
NTR
OL
MAXIM
U
M
S
PEE
D
AIR EX
C
HAN
G
E IN PR
OG
RE
SS
MIN.
MAX.
CONTINUOUS
CONTINUOUS
INTERMITTENT
T
INTERMITTENT
20 MI
M
N
.
N
N
ON
ON
40 MIN.
M
OFF
OF
C
O
M
Z
O
E
S
U
M
M
E
R
VC0028
B
A
11.2 OPTIONAL CONTROL
First, turn OFF the main control device (Basic or Electronic) before checking the remote optional control.
20/40/60-MINUTE PUSH-BUTTON TIMER:
Activate the push button. Within 2 seconds, push one time for 20 minutes, two times for
40 minutes or three times for a 60-minute activation.
Results expected:
1. Motor speed: high for 20, 40 or 60 minutes.
2. Indicator light goes “ON” and flashes every 5 seconds (one time to indicate a
20-minute operation, two times for a 40-minute, and three times for a 60-minute
operation).
3. Air exchange indicator light goes “ON” (Electronic wall control only).
NOTE: To stop activation, push one more time.
VC0046
20 min.
40 min.
60 min.