38
SECTION 4
MAINTENANCE
5. Install fingers and blank plates correctly with edges
interlocked and no space between edges.
Figure 4-21.
Top Finger
Incorrect - Too
Much Space
Blank Plate
Tab on Outer Plate of Finger
Located in Groove
Top Finger
Incorrect - Too
Much Space
Blank Plate
Tab on Outer Plate of Finger
Located in Groove
Top Finger
Correct -
Edges Overlap
Completely
Blank Plate
Tab on Outer Plate of Finger
Located in Groove